- 祥情信息
This machine use fixed original liquid measuring tank. When release agent is mixing,it can keep ration release agent.With the ball sensor switch working,it can win a stable miming effect;the viscosity ratio can be adjusted from 50:1 up to 250:1.
Feature: The application of this machine is broad.It can be used for mixing common chemicals or special chemi-cals. Its assembly is simple and easy to maintain.
1.When the solution reaches the low level limit,the measuring pump and the water valve will automatically open,starts replenishing until the solution reaches the upper limit.
2.When the original release agent reaches the low level limit,the yellow light will turn on,and the alarm will sound,please replenish the release agent.
3.When the solution output pressure is below 3bar,the red signal light will turn on the alarm will sound. Please clean or change inlet filter and check the air pressure(above 0.5Mpa as norm).